SERIE BE-W

WALL BOX 1 BASE TIPO 2

Type 2 3P+N+T 32A 400V~ 22kW 32A 400V 3P+N+T IP54 IK08 OCPP 1.6 JSON

Cod. 205.W69-D0

Fuera de Producción Ver producto de reemplazo Smart Wall Box in halogen-free engineering plastics, for wall assembly, equipped with display and Type 2 socket, 3P+N+E 32A 400V, 22kW, fitted with safety shutters in compliance with standard IEC/EN 62196-2, equipped with Energy Meter, and RFID user identification and authorisation system.
Suitable for electric vehicle charging in «mode 3» in compliance with standard EN61851-1. Version for domestic charging in absolute safety, featuring Power Management function, allowing the vehicle charging current to be adapted based on the user’s contractual power and the current absorbed by domestic loads, thus preventing the main meter from unexpectedly tripping.
The WEB-NET version allows remote monitoring through our standard Management System. Exclusive design with «Dual Feel Sensitive» finish, highly resistant to UV rays, high-level IP54 protection against dust and water with the possibility for personalisation.
Serie BE-W
WALL BOX 1 BASE TIPO 2
POLÍMERO TÉCNICO
32A
400V
50/60Hz
3P+N+T
IP54
-30°C/+50°C
GW 650°C
IK08
GRIS OSCURO
Resistente
UV resistant
MURAL
235x370x115mm

Product

EAN code
8001636447803
INTRASTAT code
8537109899
Net weight
4.412 KG
Cantidad mínima
1

Packaging

Packaging Carton
Quantity
1
EAN code
8001636447803
Depth
640.0 MM
Width
320.0 MM
Height
140.0 MM
Volume
28672.0 CCM
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
PRO
Type 2 3P+N+T 32A 400V~ 22kW
LCD 2x20 char
Autenticación RFID
Ethernet
OCPP 1.6 JSON
  • charge in mode 3 with pwm circuit pilot
  • predisposition for serial communication
  • energy metering and current consumption
  • working in mode stand-alone free or personal
  • identification of authorized user
  • protection against direct contact Safety Child Shutters
  • identification of connected cord-set size
  • interfacing with OCPP Central Station
  • charge managing in case of power outage
  • managing of latching system
  • POWER MANAGEMENT function (automatic modulation of charge current depending contractual power and power used by house).
  • 1 terminal strip 5x10mm²
  • 1 power supply 24Vdc 36W
  • 1 fuse holder 1P+N gG 4A
  • 1 DC Leakage detector
  • 1 RBG led stripes
  • 1 reader RFID 13,56MHz
  • 1 backup battery
  • 1 stop charge push-button (mode free)
  • 1 control card
  • 1 lcd display 2x20 rows backlight
  • 1 local server wired with OCPP 1.6J protocol
  • 1 modular contactor 4P 40A 24Vdc
  • 1 digital energy meter 3P+N 65/80A (external)
  • 1 digital energy meter 3P+N 80A
  • upstream protections (by the installer):
  • 1 circuit breaker 3P+N C40 30mA ist. A
Wall mounting box in thermoplastic material halogen free resistant to impact and UV rays.<br> Equipped with:<br> 1 socket Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, maximum supply current 32A three-phase 400Vac (22kW).<br> Automatic modulation of charge current depending contractual power and power used by house.<br> Complete with:<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK08.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.
thumbnail
RCM
Regulatory Compliance Mark
thumbnail
EAC
Eurasian Conformity
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
¿Necesita la hoja técnica del producto en formato pdf e imprimible?
¿Necesita documentación técnica, manuales, hojas de instrucciones o certificados?

¿Tiene el número de serie de su producto ?

¿Necesitas visualizar el producto en 3D?
* La imagen del producto puede ser indicativa

Profundización

Scame Matelial Electro S.L.
Polígono El Canyet, nave 7D
08754 El Papiol (Barcelona)


Scame Parre Spa

Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel: 0039035705000​​​​​​​


©2023 Scame Parre S.p.a. - VAT IT00137900163