- Doméstico 634660
- Material elétrico em blister 634915
- Adaptadores domésticos 634912
- Enroladores de cabo domésticos 634913
- Tomadas múltiplas domésticas 634917
- Fichas e tomadas domésticas 634911
- Seção 1.4 634914
- TV/SAT - TEL - DATA 634916
- Wiring devices 634918
- Série BASIC (8000) 635106
- Série EVOLUTION 635107
- Série EVOLVE 635104
- Série FUTURA 635100
- Série GEA 635102
- Série GLENO 635103
- Série INNOVA 635095
- Série KOMPAS 635096
- Série LUXURY 635099
- Série METALCLAD 635105
- Série MIA 635110
- Série NEXTA 635098
- Série OPERA 635094
- Série PAVIBOX 635101
- Série PROTECTA 635097
- Série UNIBOX +EVOLUTION 635108
- Série UNIBOX +EVOLVE 635109
- E-Mobility 634664
- AC charging stations 635466
- Cabos de carregamento 635463
- Connessione 635465
- DC charging stations 635467
- E-bike charging stations 635464
- Áreas de risco Ex 634663
- Indústria 634661
- Seção 3.1 635570
- Empty enclosures 635564
- Plugues e tomadas industriais para altas correntes 635563
- Tomadas interbloqueadas IOT 635573
- Plugues e tomadas industriais 635565
- Acessórios para plugues y tomadas 636901
- Tomadas móveis industriais 636907
- Socket for domestic applications 636903
- Plugues de embutir 636905
- Tomadas de embutir 636909
- Plugues móveis 636904
- Fichas e tomadas para aplicações específicas 636910
- Plugues fixos de parede 636906
- Tomadas de parede 636908
- Tomadas de parede - SWITCH 636902
- Adaptadores industriais 635571
- Enrolador de cabo industriais 635572
- Seção 2.5 635568
- Connettori multipolari 635569
- Switched interlocked socket outlets 635566
- Interruptores 635567
- Instalação 634662
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
SÉRIE ADVANCE-GRP[GD]
TOMADA BLOQUEADA
125A 3P+N+T 3h 380V 50Hz / 440V 60Hz 480-500V 50Hz 60Hz II 2GD Bornes conexión brida tornillo Con enclavamiento mecánico EAC [Eurasian Conformity]
Cod. 504.125874.RU
Série comercial
Série ADVANCE-GRP[GD]
Descrição sintéica
TOMADA BLOQUEADA
Versão de montagem
PAREDE
Corrente nominal
125A
Polos
3P+N+T
Posição horária
3h
Tensão nominal
380V 50Hz / 440V 60Hz
480-500V
Frequência
50Hz
60Hz
Cor
PRETO
Material
GRP Glass Reinforced Polyester
Grau de proteção
Splash proof
Grau de proteção IP
IP66
Grau de proteção IK
7J
Conector borne
Bornes conexión brida tornillo
Material de contacto
CuZn (latão)
Entrada cabo
1xM50
Working temperature
-35°C/+40°C
GLOW WIRE
GW 960°C
Auto-extinguível UL94
V0
Group and categories EX
II 2GD
Ambient temperature Ta min
-35 °C
Ambient temperature Ta max
40 °C
Opções
Con enclavamiento mecánico
EAC [Eurasian Conformity]
Cadeado
ø6,3mm
Catalogue notes
AtEX [ATmosphères EXplosibles]: para aplicações em atmosferas potencialmente explosivas.
Pode solicitar a configuração personalizada da entrada do cabo para toda a série da tomada ADVANCE-GRP[GD].
Todas as versões incluem bucins Ex e furo perfurado.
Product
EAN code
8001636087900
INTRASTAT code
8536699099
Net weight
0 KG
Quantidade Mínima
1
EN 60309-1/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 60309-4 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Switched socket-outlets and connectors, with or without interlock |
EN 60309-2/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-2/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-1/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 1: General requirements |
IEC 60079-31 (2013) | [International Standard] Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
IEC 60079-0 (2011) | [International Standard] Electrical Apparatus for Explosive Gas Atmospheres - Part 0: General Requirements. |
EN 60079-7 (2007) | [European Standard] Explosive atmospheres. Equipment protection by increased safety "e" |
EN 60309-2 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
DIRECTIVE ATEX 2014/34/UE | [European Directives] Atmosphere Explosive |
IEC 60079-1 (2007-04) | [International Standard] Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d". |
IEC 60309-4 (2012) | [International Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 4: Switched socket-outlets and connectors with or without interlock |
IEC 60079-7 (2006-07) | [International Standard] Explosive atmospheres - Part 7: Equipment protection by increased safety "e". |
EN 60309-1 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 60079-0 (2012) | [European Standard] Explosive atmospheres. General requirements. |
EN 60309-4/A1 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Switched socket-outlets and connectors, with or without interlock |
IEC 60309-2 (2012) | [International Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part: 2: Dimensional interchangeability requirements for pin and contact-tube accessories |
EN 60079-31 (2014) | [European Standard] Explosive atmospheres. Equipment dust ignition protection by enclosure "t" |
IEC 60309-1 (2012) | [International Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 1: General requirements |
EN 60079-1 (2007) | [European Standard] Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosures "d" |

Notifica ATEX
Product quality assurance notification

EAC Atex
Eurasian Conformity

UE
Declaratiòn de conformidad

EAC
Eurasian Conformity