Catálogo
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SÉRIE BE-W

WALL BOX CABLE+TOMA T2

Type 2 1P+N+T 32A 230V~ 7,4kW 32A 230V 1P+N+T IP54 IK08 Tipo 2 4m OCPP 1.6 JSON

Cod. 205.W73-S0

Em exaustão Ver produto de substituição
Wall Box in halogen-free engineering plastics, for wall assembly, equipped with display and with 1 connector Type 2 32A 230vac 7.4 kW with cable, in accordance with IEC/ EN 62196-2, equipped with Energy Meter and user recognition system RFID.
Connection with LAN system for remote management and control.
The Wall Box can be a MASTER in station networks. Compliant with «MODE 3» of the international standard IEC/EN 61851-1.
WEB-NET version ideal for the management of systems equipped with multiple charging points for recharging in both public and private. Exclusive design with «Dual Feel Sensitive» finish, highly resistant to UV rays, high-level IP54 protection against dust and water with the possibility for personalization. Complete with cable holder in technopolymer, anthracite color.
Série comercial
Série BE-W
Descrição sintéica
WALL BOX CABLE+TOMA T2
Material
TECNOPOLÍMERO
Cable length
4m
Cable section
3G6+1x0,5mm²
Corrente nominal
32A
Tensão nominal
230V
Frequência
50/60Hz
Polos
1P+N+T
Grau de proteção IP
IP54
Working temperature
-30°C/+50°C
GLOW WIRE
GW 650°C
Grau de proteção IK
IK08
Cor
ANTRACITE
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
PAREDE
Dimensions
235x370x115mm
Catalogue notes
Completo com suporte cabo.

Product

EAN code
8001636437835
INTRASTAT code
8537109899
Net weight
5.543 KG
Quantidade Mínima
1

Packaging

Packaging Carton
Quantity
1
EAN code
Depth
628.0 MM
Width
440.0 MM
Height
207.0 MM
Volume
57198.24 CCM
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
Version
PRO
EV standard
Type 2 1P+N+T 32A 230V~ 7,4kW
Com cabo integrado
Tipo 2
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
Ethernet
Communication protocol
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
interfacing with OCPP Central Station
power contactor aperture monitoring
EV equipment
1 power supply 24Vdc 36W
1 DC Leakage detector
1 fuse holder 1P+N gG 4A
1 control card
1 stop charge push-button (mode free)
1 lcd display 2x20 rows backlight
1 RBG led stripes
1 reader RFID 13,56MHz
1 local server wired with OCPP 1.6J protocol
1 modular contactor 2P 40A 24Vdc
1 digital energy meter 1P+N 40A
1 cable holder in technopolymer
1 terminal strip 3x10mm²
1 cable 3G6+1x0,5mm² 4m
EV excluded
upstream protections (by the installer):
1 circuit breaker 1P+N C40 30mA ist. A
1 shunt trip release 24Vdc
EV specifications
Wall mounting box in thermoplastic material halogen free resistant to impact and UV rays.<br> Equipped with:<br> 1 connector Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging and case C (mobile connector with cable) in compliance with IEC/EN 61851-1, maximum supply current 32A single-phase 230Vac (7,4kW).<br> Complete with: Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Control system for power contactor aperture monitoring.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK08.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.<br>
RCM
Regulatory Compliance Mark
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
thumbnail
EAC
Eurasian Conformity
Você precisa da Folha Técnica do produto ?
Baixe em formato pdf
Você precisa de Documentação ou Certificação do produto ?

Tem o número de série do seu produto ?

Você precisa de Documentação ou Certificação do produto ?

Aprofundamento

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel. 
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163