- Doméstico 637496
- Material elétrico em blister 637751
- Adaptadores domésticos 637748
- Enroladores de cabo domésticos 637749
- Tomadas múltiplas domésticas 637753
- Fichas e tomadas domésticas 637747
- Seção 1.4 637750
- TV/SAT - TEL - DATA 637752
- Wiring devices 637754
- Série BASIC (8000) 637942
- Série EVOLUTION 637943
- Série EVOLVE 637940
- Série FUTURA 637936
- Série GEA 637938
- Série GLENO 637939
- Série INNOVA 637931
- Série KOMPAS 637932
- Série LUXURY 637935
- Série METALCLAD 637941
- Série MIA 637946
- Série NEXTA 637934
- Série OPERA 637930
- Série PAVIBOX 637937
- Série PROTECTA 637933
- Série UNIBOX +EVOLUTION 637944
- Série UNIBOX +EVOLVE 637945
- E-Mobility 637500
- AC charging stations 638302
- Cabos de carregamento 638299
- Connessione 638301
- DC charging stations 638303
- E-bike charging stations 638300
- Áreas de risco Ex 637499
- Indústria 637497
- Seção 3.1 638406
- Empty enclosures 638400
- Plugues e tomadas industriais para altas correntes 638399
- Tomadas interbloqueadas IOT 638409
- Plugues e tomadas industriais 638401
- Acessórios para plugues y tomadas 639737
- Tomadas móveis industriais 639743
- Socket for domestic applications 639739
- Plugues de embutir 639741
- Tomadas de embutir 639745
- Plugues móveis 639740
- Fichas e tomadas para aplicações específicas 639746
- Plugues fixos de parede 639742
- Tomadas de parede 639744
- Tomadas de parede - SWITCH 639738
- Adaptadores industriais 638407
- Enrolador de cabo industriais 638408
- Seção 2.5 638404
- Connettori multipolari 638405
- Switched interlocked socket outlets 638402
- Interruptores 638403
- Instalação 637498
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
SÉRIE CA
PILLAR CA 2 SOCKETS WITH LOCK
Type 2 3P+N+T 32A 400V~ 22kW 63A 400V 3P+N+T IP54 IK10 OCPP 1.6 JSON
Cod. 204.CA23D-T2T2E
Painted steel column equipped with 2 Type 2 3P+N+T 32A 400 Vac 22 kW sockets in compliance with IEC/EN 62196-2. Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1. Equipped with RFID Card reader for user identification and management. Equipped with scokets with special plug locking system and with exclusive anti-vandal access system (Type 2). It is particularly suited for installation in public places. Customisable fron panel in polycarbonate, resistant to UVA rays. High degree of protection against dust and water.
Série comercial
Série CA
Descrição sintéica
PILLAR CA 2 SOCKETS WITH LOCK
Material
METAL ENVERNIZADO
Corrente nominal
63A
Tensão nominal
400V
Frequência
50/60Hz
Polos
3P+N+T
Grau de proteção IP
IP54
Working temperature
-30°C/+50°C
Grau de proteção IK
IK10
Cor
CINZA
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
EM CIMA DA TORRE
Dimensions
385x1510x263mm
Product
EAN code
8001636100869
INTRASTAT code
8537109899
Net weight
54 KG
Quantidade Mínima
1
Packaging
Packaging Carton
EAN code
Quantity
1
Depth
405.0 MM
Width
285.0 MM
Height
1525.0 MM
Volume
176023.125 CCM
DIRECTIVE EMC 2014/30/UE | [European Directives] Electromagnetic Compatibility Directive |
IEC 61439-7 (2018) | [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations |
DIRECTIVE LOW VOLTAGE 2014/35/UE | [European Directives] Low Voltage Directive |
EN IEC 61851-1 (2019) | [European Standard] Electric vehicle conductive charging system - Part 1: General requirements |
Version
PRO
EV standard
Type 2 3P+N+T 32A 400V~ 22kW
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
Ethernet
WiFi
GSM
Communication protocol
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
identification of connected cord-set size
charge managing in case of power outage
interfacing with OCPP Central Station
managing of lid locking and latching system
Load Balancing function
wireless connection to web
EV equipment
1 base with separation chamber
1 backup battery
1 local server wired with OCPP 1.6J protocol
2 DC Leakage detectors
2 control cards
2 stop charge push-buttons (mode free)
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
1 lighting head in translucent and RGB led
1 router Wi-Fi/4G
1 couple of front panels in polycarbonate
2 modular contactors 4P 40A 24Vdc
1 terminal strip 10x35mm²
2 power supplies 24Vdc 36W
2 fuse holders 1P+N gG 4A
2 digital energy meters 3P+N 80A
EV excluded
upstream protections (by the installer):
2 circuit breakers 3P+N C40 30mA ist. A
EV specifications
Pillar in painted galvanized steel prepared for floor installation with basement with function of anti-condensation separation room.<br> RGB LED light head with three colours indicating the station's operating status.<br> Front panels in polycarbonate with the possibility of customization with the customer's logo or brand.<br> Equipped with:<br> 2 sockets Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, vandal-proof lockable lid, maximum supply current 32A three-phase 400Vac (22kW).<br> Coplete with:<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Device for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the event of power outage.<br> RFID reader for user recognition and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD display for messages and diagnostic management with the possibility of changing the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.

UKCA marking
UK Conformity Assessed

UE
Declaratiòn de conformidad