Catálogo
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SÉRIE CA

PILLAR CA 1 CONNECT. T2 RFID

Type 2 3P+N+T 63A 400V~ 44kW 63A 400V 3P+N+T IP54 IK10 Tipo 2 3m

Cod. 204.CA13R-T26

Fora de Produção Painted steel column equipped with 1 Type 2 3P+N+T 63A 400 Vac 44 kW socket in compliance with IEC/EN 62196-2 Suitable for charging electric vehicles in «mode 3» in compliance with the IEC/EN 61851-1 standard with type-C connection. Particularly suitable for installation in public areas. Equipped with RFID Card for user identification and management Charging station having a socket equipped with a special system that checks for the correct opening of the contactor. Customisable panel, resistant to UVA rays, high degree of protection against dust and water (IP54)
Série CA
PILLAR CA 1 CONNECT. T2 RFID
METAL ENVERNIZADO
3m
5G10+1x0,5mm²
63A
400V
50/60Hz
3P+N+T
IP54
-30°C/+50°C
IK10
CINZA
Resistente
UV resistant
EM CIMA DA TORRE
385x1510x263mm

Product

EAN code
8001636285597
INTRASTAT code
8537109899
Net weight
55.5 KG
Quantidade Mínima
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
BUSINESS
Type 2 3P+N+T 63A 400V~ 44kW
Tipo 2
LCD 2x20 char
RFID authentication
None
  • charge in mode 3 with pwm circuit pilot
  • predisposition for serial communication
  • energy metering and current consumption
  • working in mode stand-alone free or personal
  • identification of authorized user
  • protection against overcurrents and electric shock
  • power contactor aperture monitoring
  • charge managing in case of power outage
  • 1 base with separation chamber
  • 1 power supply 24Vdc 36W
  • 1 fuse holder 1P+N gG 4A
  • 1 DC Leakage detector
  • 1 backup battery
  • 1 reader RFID 13,56MHz
  • 1 stop charge push-button (mode free)
  • 1 control card
  • 1 lcd display 2x20 rows backlight
  • 1 terminal strip 5x35mm²
  • 1 lighting head in translucent and RGB led
  • 1 couple of front panels in polycarbonate
  • 1 shunt trip release 24Vdc
  • 1 circuit breaker 3P+N C63 30mA ist. A
  • 1 industrial contactor 4P 63A 24Vdc
  • 1 digital energy meter 3P+N 80A
  • 1 inlet dummy for connector storage
  • 1 cable 5G10+1x0,5mm² 3m
Charging station for electric vehicles with floor installation via galvanised steel base (500 X 410 mm) acting as a condensation separation chamber, equipped with studs on which to fix the column using M8 nuts (centre distance 250 X 170 mm).<br>Structure in galvanised and painted sheet steel equipped with front panels in plexiglass with the possibility of customisation with the customer's logo or brand.<br>Column equipped with a type 2 mobile socket (cable + mobile connector corresponding to a case C connection) in compliance with CEI EN 62196-2 and suitable for charging in mode 3 in compliance with CEI EN 61851-1.<br>The socket unit is mounted onto the vehicle to avoid tampering and disconnections while charging.<br>The IPXXD degree of protection required by the standard is provided through a control system to verify the correct opening of the power contactor.<br>Maximum deliverable current 63 A three-phase (44 kW).<br>Column complete with automatic and differential protection devices (type B for three-phase socket) and digital meter for the measurement of the energy delivered and the control of the absorbed current.<br>LCD display for messages and diagnostic management with the possibility of changing the language through a simple button, backup batteries to ensure continuity of service in the event of power loss.<br>RFID reader for user recognition and management of the charge. Operation in FREE or PERSONAL stand-alone mode.<br>Set up for communication over RS485 serial line (NET mode with management via server).<br>Operating temperature -25°C to +40°C, IK10 impact resistance, casing with IP44 degree of protection.<br>Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br>
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad

* A imagem do produto pode ser indicativa

Você precisa da Folha Técnica do produto ?
Você precisa de Documentação ou Certificação do produto ?

Tem o número de série do seu produto ?

Você precisa de Documentação ou Certificação do produto ?

Aprofundamento

Produtos relacionados

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel. 
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163