Catálogo
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SERIE CA

COLUMNA CA 2 BASES CON BLOQUEO

Type 2 3P+N+T 32A 400V~ 22kW 63A 400V 3P+N+T IP54 IK10 OCPP 1.6 JSON

Cod. 204.CA23D-T2T2E

Fuera de Producción Ver producto de reemplazo
Painted steel column equipped with 2 Type 2 3P+N+T 32A 400 Vac 22 kW sockets in compliance with IEC/EN 62196-2. Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1. Equipped with RFID Card reader for user identification and management. Equipped with scokets with special plug locking system and with exclusive anti-vandal access system (Type 2). It is particularly suited for installation in public places. Customisable fron panel in polycarbonate, resistant to UVA rays. High degree of protection against dust and water.
Serie comercial
Serie CA
Descripción
COLUMNA CA 2 BASES CON BLOQUEO
Material
METAL BARNIZADO
Intensidad nominal
63A
Tensión nominal
400V
Frecuencia nominal
50/60Hz
Polos
3P+N+T
Grado de protección IP
IP54
Temperatura de ejercicio
-30°C/+50°C
Grado de protección IK
IK10
Color
GRIS
Solución salina
Resistente
UV protection
UV resistant
Tipo de instalación
TORRETA
Dimensiones
385x1510x263mm

Product

EAN code
8001636100869
INTRASTAT code
8537109899
Net weight
54 KG
Cantidad mínima
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
405.0 MM
Width
285.0 MM
Height
1525.0 MM
Volume
176023.125 CCM
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Versión
PRO
EV standard
Type 2 3P+N+T 32A 400V~ 22kW
IHM (Interface Hombre-Máquina)
LCD 2x20 char
Autenticacion de usuario
Autenticación RFID
Connectivity
Ethernet
WiFi
GSM
Protocolo de comunicación
OCPP 1.6 JSON
EV funciones
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
identification of connected cord-set size
charge managing in case of power outage
interfacing with OCPP Central Station
managing of lid locking and latching system
Load Balancing function
wireless connection to web
EV equipo
1 base with separation chamber
1 backup battery
1 local server wired with OCPP 1.6J protocol
2 DC Leakage detectors
2 control cards
2 stop charge push-buttons (mode free)
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
1 lighting head in translucent and RGB led
1 router Wi-Fi/4G
1 couple of front panels in polycarbonate
2 modular contactors 4P 40A 24Vdc
1 terminal strip 10x35mm²
2 power supplies 24Vdc 36W
2 fuse holders 1P+N gG 4A
2 digital energy meters 3P+N 80A
EV excluido
upstream protections (by the installer):
2 circuit breakers 3P+N C40 30mA ist. A
EV capitolato
Pillar in painted galvanized steel prepared for floor installation with basement with function of anti-condensation separation room.<br> RGB LED light head with three colours indicating the station's operating status.<br> Front panels in polycarbonate with the possibility of customization with the customer's logo or brand.<br> Equipped with:<br> 2 sockets Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, vandal-proof lockable lid, maximum supply current 32A three-phase 400Vac (22kW).<br> Coplete with:<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Device for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the event of power outage.<br> RFID reader for user recognition and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD display for messages and diagnostic management with the possibility of changing the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
¿Necesita la fiche técnica del producto en formato pdf e imprimible?
Descargar la Ficha Técnica
¿Necesita documentación técnica, manuales, hojas de instrucciones o certificados?

¿Tiene el número de serie de su producto ?

¿Necesita documentación técnica, manuales, hojas de instrucciones o certificados?

Profundización

Productos relacionados

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163