- Doméstico 637496
- Productos en blister 637751
- Adaptadores domésticos 637748
- Enrollacables domesticos 637749
- Bases múltiples domésticas 637753
- Clavijas y bases domésticas 637747
- Portalámparas e interruptores 637750
- TV/DATA 637752
- Mecanismos 637754
- Serie BASIC (8000) 637942
- Serie EVOLUTION 637943
- Serie EVOLVE 637940
- Serie FUTURA 637936
- Serie GEA 637938
- Serie GLENO 637939
- Serie INNOVA 637931
- Serie KOMPAS 637932
- Serie LUXURY 637935
- Serie METALCLAD 637941
- Serie MIA 637946
- Serie NEXTA 637934
- Serie OPERA 637930
- Serie PAVIBOX 637937
- Serie PROTECTA 637933
- Serie UNIBOX +EVOLUTION 637944
- Serie UNIBOX +EVOLVE 637945
- E-Mobility 637500
- Estaciones de carga en AC 638302
- Cables de carga 638299
- Conexiones 638301
- Estaciones de recarga en DC 638303
- Estaciones de carga para e-bike 638300
- Para uso de emergencia 981959
- Para uso general - SPECIAL 981957
- Para uso general 981958
- Áreas peligrosas Ex 637499
- Industria 637497
- Cuadros cableados 638406
- Envolventes 638400
- Clavijas y bases industriales de alta intensidad 638399
- Bases con bloqueo IOT 638409
- Clavijas y bases industriales 638401
- Adaptadores industriales 638407
- Enrollacables industriales 638408
- Aparatos de iluminación 638404
- Connettori multipolari 638405
- Bases con dispositivo de bloqueo 638402
- Interruptores 638403
- Instalación 637498
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
SERIE CA
COLUMNA CA 2 BASES CON BLOQUEO
DE 2P+T 16A 230V~ 3,7kW 16A 400V 3P+N+T IP54 IK10 OCPP 1.6 JSON
Cod. 204.CA21B-UNUNA
Serie CA
COLUMNA CA 2 BASES CON BLOQUEO
METAL BARNIZADO
16A
400V
50/60Hz
3P+N+T
IP54
-30°C/+50°C
IK10
GRIS
Resistente
UV resistant
POSTE
385x1510x263mm
Product
EAN code
8001636036953
INTRASTAT code
8537109899
Net weight
51 KG
Cantidad mínima
1
Packaging
Packaging Carton
Quantity
1
EAN code
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
| EN 61439-3 (2012-04) | [European Standard] Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
| DIRECTIVE EMC 2014/30/UE | [European Directives] Electromagnetic Compatibility Directive |
| DIRECTIVE LOW VOLTAGE 2014/35/UE | [European Directives] Low Voltage Directive |
PRO
DE 2P+T 16A 230V~ 3,7kW
LCD 2x20 char
Autenticación RFID
Ethernet
OCPP 1.6 JSON
- protection against overcurrents and electric shock
- predisposition for serial communication
- energy metering and current consumption
- working in mode stand-alone free or personal
- identification of authorized user
- protection against direct contact Safety Child Shutters
- interfacing with OCPP Central Station
- charge managing in case of power outage
- managing of lid locking and latching system
- load Balancing function
- 1 base with separation chamber
- 1 power supply 24Vdc 36W
- 1 fuse holder 1P+N gG 4A
- 1 backup battery
- 1 local server wired with OCPP 1.6J protocol
- 2 control cards
- 1 terminal strip 5x35mm²
- 2 readers RFID 13,56MHz
- 1 lighting head in translucent and RGB led
- 2 lcd display 2x20 rows backlight
- 2 stop charge push-buttons (mode free)
- 1 couple of front panels in polycarbonate
- 1 main switch 4P 40A
- 2 digital energy meters 1P+N 40A
- 2 circuit breakers 1P+N D20 30mA ist. A
- 2 modular contactors 2P 25A 24Vdc
Pillar in painted galvanized steel prepared for floor installation with basement with function of anti-condensation separation room.<br> RGB LED light head with three colours indicating the station's operating status.<br> Front panels in polycarbonate with the possibility of customization with the customer's logo or brand.<br> Equipped with:<br> 2 German sockets type (domestic), equipped with shutter protection (IPXXD degree of protection without any additional devides), lockable lid even with plug inserted to avoid unintentional withdraw, maximum supply current 16A single-phase 230Vac (3,7kW), the use of this sockets is allowed only in areas where is not compulsory the mode 3.<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with EN 61439-3 standards and complete with CE marking.<br>
UKCA marking
UK Conformity Assessed
UE
Declaratiòn de conformidad